This standard establishes minimum requirements for material, design, fabrication, erection, and inspection for vertical, cylindrical, aboveground, closed- and open-top, welded storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93 °C (200 °F) or less.

This standard provides industry with tanks of adequate safety and reasonable economy for use in the storage of petroleum, petroleum products, and other liquid products. This standard does not present or establish a fixed series of allowable tank sizes; instead, it is intended to permit the Purchaser to select whatever size tank may best meet their needs. This standard is intended to help Purchasers and Manufacturers in ordering, fabricating, and erecting tanks; it is not intended to prohibit Purchasers and Manufacturers from purchasing or fabricating tanks that meet specifications other than those contained in this standard.

Product Details

Edition:
13th
Published:
03/01/2020
Number of Pages:
514
File Size:
1 file , 10 MB
Redline File Size:
2 files , 29 MB
Product Code(s):
C65013, C65013, C65013
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria
Posted in API

Click here to purchase
Please note: The redline edition of this publication is a comparison of the original 12th edition to the original 11th edition, it does not incorporate any future addenda.

Please note: as a requirement of the API committee that develops this publication, some addendums may not be available as standalone files, they are simply incorporated into the base publication.

This standard establishes minimum requirements for material, design, fabrication, erection, and inspection for vertical, cylindrical, aboveground, closed- and open-top, welded storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93 °C (200 °F) or less.

This standard is designed to provide industry with tanks of adequate safety and reasonable economy for use in the storage of petroleum, petroleum products, and other liquid products. This standard does not present or establish a fixed series of allowable tank sizes; instead, it is intended to permit the Purchaser to select whatever size tank may best meet his needs. This standard is intended to help Purchasers and Manufacturers in ordering, fabricating, and erecting tanks; it is not intended to prohibit Purchasers and Manufacturers from purchasing or fabricating tanks that meet specifications other than those contained in this standard.

Product Details

Edition:
12th
Published:
03/01/2013
Number of Pages:
511
File Size:
1 file , 27 MB
Redline File Size:
2 files , 38 MB
Part of:
API 650 & 653 SET, API 650 and 653 SET
Product Code(s):
CN2995, C65012, C, CN2995, C65012, C, C, C, CN2995
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria
Posted in API

Click here to purchase
API Std 650 establishes minimum requirements for material, design, fabrication, erection, and testing for vertical, cylindrical, aboveground, closed- and open-top, welded carbon or stainless steel storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This Standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93°C (200°F) or less.

Interested in related datasheets? Click here!

Product Details

Edition:
11th
Published:
06/01/2007
Number of Pages:
376
File Size:
1 file , 11 MB
Part of:
API 650 & 653 SET
Product Code(s):
C65011C, C65011, C65011R, C65011, C65011R, C65011C, C65011R
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria
Posted in API

Click here to purchase
Includes all addendums.

This standard is designed to provide the petroleum industry with tanks of adequate safety and reasonable economy for use in the storage of petroleum, petroleum products, and other liquid products commonly handled and stored by the various branches of the petroleum industry. It is intended to help purchasers and manufacturers in ordering, fabricating, and erecting tanks. Standard 650, Tenth Edition, covers material, design, fabrication, erection, and testing requirements for vertical, cylindrical, aboveground, closed- and open-top, welded steel storage tanks in various and capacities for internal pressures approximating atmospheric pressure, but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported; and to tanks in nonrefrigerated service, that have a maximum operating temperature of 90 deg C (200 deg F).

Product Details

Edition:
10th
Published:
11/01/1998
Number of Pages:
296
File Size:
1 file , 3.3 MB
Product Code(s):
C65010, C65010, C65010
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria
Posted in API